Anthony Squires EngTech MIET, Electrician and Engineering Technician, examines whether historic alterations to electrical installations in high rise dwellings have always aligned with the life safety intent of building regulations and fire strategy.
In many high rise residential buildings, the fire and evacuation strategy relies upon occupants escaping from their flat into a protected common corridor or stair. Within the dwelling itself, however, the only means of escape commonly passes through the entrance hall. This internal route is not incidental. It forms a critical part of the overall protected escape strategy.
Times have changed
In a significant number of flats, the electrical consumer unit is located within the entrance hall but now installed outside of the original recessed metal mantel cabinet, removing the containment originally intended to restrict fire spread on the escape route.
This places electrical distribution equipment at precisely the location where tolerance for fire risk should be lowest.
The original design of many high rise buildings didn’t place electrical equipment openly within the entrance hall. Consumer units were commonly installed within recessed metal mantel enclosures integrated into the building fabric.
This arrangement was deliberate. It reflected architectural and fire safety decisions intended to contain potential ignition sources and preserve a safe internal escape path.
Over time, refurbishment and upgrade programmes altered that original arrangement.
Consumer units were removed from their metal enclosures and replaced with surface mounted PVC units located within the entrance hall but now installed outside of the original metal mantel cabinet.
These changes have often been described as compliant at the time. However, in my opinion, that assumption warrants closer examination when viewed through the wider context of life safety legislation.
Even in the 1990s, manufacturers’ instructions required that electrical installations comply with the Building Regulations.
Part B of the Building Regulations has long required buildings to be designed so occupants can reach a place of safety via a suitable and protected means of escape.
This requirement didn’t originate with recent amendments. It has existed for decades as a fundamental fire safety principle.
Where electrical equipment was removed from its original metal containment and reinstalled in combustible enclosures directly on the escape route, it is reasonable to question whether those alterations fully aligned with the intent of Part B.
While the electrical standards of the time may not have prohibited PVC enclosures, the broader obligation to preserve a protected path of egress remained.
An evolving risk
As these installations continue in service, their risk profile evolves. Electrical systems are subject to progressive ageing and cumulative degradation.
Loose terminations, thermal cycling, insulation breakdown, mechanical stress, and historic workmanship issues are well understood failure mechanisms within electrical engineering. These risks are not static, and they increase over time.
This is also not speculative. Fire incidents arising from failures within electrical distribution equipment are well documented.
Amendment 3 to BS 7671, introduced in 2016, formally recognised this by requiring consumer units in domestic premises to be constructed of non-combustible material or enclosed within non-combustible cabinets. This amendment reflected observed risk rather than creating a new one.
The amendment was not retrospective. As a result, large numbers of PVC consumer units remain installed on the sole means of escape within dwellings in high rise buildings, often positioned outside of their originally designed protective enclosures.
This places increased importance on periodic inspection and informed engineering judgement. BS 7671 requires installations to be assessed for continued safety, not merely historic compliance.
In high rise residential settings, where escape may depend upon a single internal route and occupants may include vulnerable persons, the location and construction of distribution equipment becomes a life safety consideration rather than a purely technical one.
The need for evidence-based evaluation
This is not an argument for indiscriminate retrospective enforcement, more that there is, I believe, a justified need for proportionate, evidence led risk evaluation.
Where combustible consumer units are positioned on internal escape routes within high rise dwellings, inspectors should consider whether the combined factors of altered building design intent, ageing equipment, and fire strategy elevate the risk beyond that of a standard dwelling. The hazard is identifiable and the risk can be assessed. The means of mitigation are known, including replacement with non-combustible enclosures or reinstatement of appropriate containment where reasonably practicable.
This is therefore a matter of professional judgement and policy alignment, not technical uncertainty.
If the collective objective is to protect life, then the treatment of fire risk on the escape route must extend beyond minimum electrical compliance and reflect the original intent of building design and fire safety legislation.