Megger
  • Made 2 Measure: Loop Testing of RCBO/RCD Circuits

    The technical team at Megger answer this month’s reader query. YOU ASKED: I’ve been working in a college ...

    The technical team at Megger answer this month’s reader query. YOU ASKED: I’ve been working in a college recently where supplies to the lab benches are protected by RCBOs with a 10ma earth leakage tri ...

    Read more
  • Loop Impedance Testing: Have We Seen The End of Uplift?

    An uplifting experience is generally considered to be something positive, but not when it comes to loop i ...

    An uplifting experience is generally considered to be something positive, but not when it comes to loop impedance testing. But what exactly is uplift, why is it a problem, and what can be done about i ...

    Read more
  • Made 2 Measure: Varying Earth Loop Impedance Test Results

    You ask: I’ve noticed that if I repeat an earth loop impedance test several times on the same circuit, th ...

    You ask: I’ve noticed that if I repeat an earth loop impedance test several times on the same circuit, the results sometimes vary a lot. Why is this and how do I decide which of the results to record ...

    Read more
  • Made 2 Measure: Why Do You Have High Zs Readings?

    The experts at Megger answer your latest testing query. YOU ASKED: When I was carrying loop impedance tes ...

    The experts at Megger answer your latest testing query. YOU ASKED: When I was carrying loop impedance tests on a recent job, I got high Zs readings on RCD protected circuits, even though the ZE and R1 ...

    Read more
  • Made 2 Measure: Nuisance Tripping

    You asked: I’ve been having a lot of trouble recently with nuisance tripping of RCDs and RCBOs. It’s ofte ...

    You asked: I’ve been having a lot of trouble recently with nuisance tripping of RCDs and RCBOs. It’s often difficult to trace the source of the problem, especially when it’s intermittent. Do you have ...

    Read more
  • How To Purge Your Loop Test Paranoia

    Megger’s Simon Wood explains why the launch of a brand new MFT could spell an end to loop test paranoia. ...

    Megger’s Simon Wood explains why the launch of a brand new MFT could spell an end to loop test paranoia. Loop testing creates more paranoia among electricians and produces more calls to our helpline t ...

    Read more
  • Megger | When Low is the Way to Go

    Many of the latest instruments for testing electrical installations offer a low voltage insulation test o ...

    Many of the latest instruments for testing electrical installations offer a low voltage insulation test option, but when is it appropriate to use a low test voltage? Simon Wood, UK Wholesale & Dis ...

    Read more
  • Megger | CableCalc+ App

    The Megger CableCalc+ App allows contractors to choose cables and calculate voltage drops quickly and eas ...

    The Megger CableCalc+ App allows contractors to choose cables and calculate voltage drops quickly and easily for electrical installations up to 25kW. New from Megger is an updated and even more versat ...

    Read more
  • Megger Extension Test Leads

    Megger has recently launched a selection of new extension test leads that facilitate direct measurement o ...

    Megger has recently launched a selection of new extension test leads that facilitate direct measurement of R2 values when testing electrical installations. The new leads from Megger are ideally suited ...

    Read more
  • Megger Savings

    Electrical contractors buying new Megger test equipment now have a great opportunity to make big savings. ...

    Electrical contractors buying new Megger test equipment now have a great opportunity to make big savings. For a limited time only Megger is offering a Safe Insulation Test Kit, which includes an MIT22 ...

    Read more